300B Electron Tube

from €1,840.00

The 300B is known around the world for its sound quality and powerful performance in both single-ended & push-pull amplifiers.

Number:
Quantity:
Add To Cart

The 300B is known around the world for its sound quality and powerful performance in both single-ended & push-pull amplifiers.

The 300B is known around the world for its sound quality and powerful performance in both single-ended & push-pull amplifiers.


The Original

We offer the original 300B with authenticity and precision. Listeners have trusted the same specs, materials, and testing standards for 85 years.


Balanced, Powerful, Refined

The Western Electric 300B sound is balanced, powerful and refined with quality bass from the lowest frequencies through the upper bass. The midrange above is a thing of beauty; dulcet tones, seductive vocals, instruments of all types dimensional and present, all heightening the participatory elements of music.


Burnished and Beautifully Seductive

High frequencies are at once transparent, lovely, sweet, burnished and beautifully seductive. The air and space between performers are extraordinary, performers appear on a quiet and focused soundstage whose width and depth are masterfully rendered. You don’t have to search to find the sweet spot with a WE 300B amplifier, it’s all around you.

Find out what tube aficionados all over the globe know, the WE 300B is the most natural, elegant and emotive triode anywhere in the known universe.


Specifications


Classification
Moderate power, filamentary triodes for Class-A service.

Application
Audio-frequency amplifier in positions where power outputs of approximately ten watts or less are required at relatively low plate voltages.

Dimensions
Dimensions, outline diagrams of the tubes and bases, and the arrangement of electrode connections to the base terminals are shown in Figures 1 and 2.

Base and Mounting
These vacuum tubes employ medium, four-pin thrust type bases suitable for use in Western Electric 143B or similar sockets. The 300B tube has the bayonet pin so located that it may also be mounted in a Western Electric 100M, 115B, or similar socket.

The tubes may be mounted in either a vertical or horizontal position. If mounted In a horizontal position, the plane of the filament, which is indicated In Figure 2, should be vertical.

Average Direct Interelectrode Capacitances
Grid to plate 15 µµf.
Grid to filament 9 µµf.
Plate to filament 4.3 µµf.

Filament Rating
Filament voltage 5.0 volts, a.c. or d.c.
Nominal filament current 1.2 amperes

The filaments of these tubes are designed to operate on a voltage basis and should be operated at as near the rated voltage as possible. When alternating current is used for heating the filament, the grid and plate returns should be connected to a center tap on the secondary of the filament transformer.

Characteristics


Average Characteristics

(Ef = 5.0 volts, a.c., Eb = 300 volts and Ec = -61 volts)
Plate current 60 milliamperes
Amplification factor 3.85
Plate resistance 700 ohms
Grid to plate transconductance 5500 micromhos

Limiting Operating Conditions for Safe Operation
(Not simultaneous ratings)
Maximum plate voltage: 450 volts
Maximum plate dissipation: 40 watts
Maximum plate current of an average tube for fixed grid bias: 70 milliamperes
Maximum plate current for manually adjusted grid bias or self-biasing circuit: 100 milliamperes

Recommended Operating Conditions
commended and maximum conditions for alternating-current filament supply are given in the table. Recommended conditions or others of no greater severity should be selected in preference to maximum conditions wherever possible. The life of the tube at maximum operating conditions will be shorter than at the recommended conditions.

Where it is necessary to operate the tube at or near the maximum plate current of 100 milliamperes, provision should be made for adjusting the grid bias of each tube independently, so that the maximum safe plate current will not be exceeded in any tube. Alternatively, a self-biasing circuit may be used, in which the grid bias for the tube is obtained from the voltage drop produced by the plate current of that tube flowing through a resistance.

Where it is necessary to use a fixed grid bias, the plate current of the average tube should be limited to a maximum value of 70 milliamperes, so that tubes having plate currents higher than the average will not exceed the maximum safe plate current.

Power Output and Distortion

Performance data including power output, second and third harmonic levels for a number of operating conditions are given in the table.

The variation of power output and harmonic levels with load resistance for several values of operating plate current is shown in Figures 7, 8 and 9, for a plate voltage of 350 volts.

The peak value of the sinusoidal input voltage, Egm, which gives the indicated power output, Pm and harmonic levels, F2m and F3m for each point in both the curves and the table, is numerically equal to the grid biasing voltage at that point. For a smaller input voltage Eg, the approximate levels may be computed from the following relations.

P=Pm(Eg/Egm)^2
F2=F2m+20 log10(Eg/Egm)
F3=F3m+40 log10(Eg/Egm)